Clean Areas for the Optical Tables
A local clean zone is a structure created and used in such a way as to minimize the retention of particles within itself. The particles are removed by laminar air flows that have passed through coarse and fine filters. In addition, the laminar air flow creates a higher pressure, which prevents particles from the environment from entering the interior of the clean zone.

Clean zones are used to create a local clean space, where the optical table and various equipment that are demanding for the cleanliness of the use environment are placed. The clean areas for the optical table consist of a frame with electrostatic curtains and an air purification unit, which includes low noise fans and HEPA coarse and fine filters.

Features:
- Production according to the customer's requirements;
- Various classes of air purification that meet international and national standards;
- The ability to complete the design with additional devices.
A local clean zone is a structure created and used in such a way as to minimize the retention of particles within itself. The particles are removed by laminar air flows that have passed through coarse and fine filters. In addition, the laminar air flow creates a higher pressure, which prevents particles from the environment from entering the interior of the clean zone.

Clean zones are used to create a local clean space, where the optical table and various equipment that are demanding for the cleanliness of the use environment are placed. The clean areas for the optical table consist of a frame with electrostatic curtains and an air purification unit, which includes low noise fans and HEPA coarse and fine filters.

Features:
- Production according to the customer's requirements;
- Various classes of air purification that meet international and national standards;
- The ability to complete the design with additional devices.
Basic parameters and dimensions
Dimensions: According to the individual requirements of the customer
Material:
____Frame: 40×40 mm steel profile
____Side walls / Doors: glass, anti-static vinyl blinds
____Cleaning unit: Aluminum composite
Lighting: > 500 lux
Cleaning Unit:
____Purity Class: ISO 6
____Coarse filter: G4
____Fine filter: HEPA14
____Air flow rate: > 0.35 m/s
____Noise level: < 60 dB
Power consumption:
____Power supply voltage: 220V, 50Hz